NAVYRA

NAVYRA

NDB NAVYRA-500 is the result of many years of experience of our company working in the field of radar and radio navigation technology.

It is an aerial non-directional beacon that can be used for both civilian and military deployments. We supplied this equipment for example for: AERO TRADE, a.s., MO of the Slovak Republic, MO of Uzbekistan, MO of Azerbaijan.

NDB NAVYRA-500 is an effective, reliable, dual approach radio beacon used as air navigation to ensure the landing of aircraft, it can be used for both stationary and mobile stations. It can be operated manually on site or remotely via intelligent software with self-control functions. It can work with "T" type antennas, UZA or other antennas with a grounding system.

Our "T" type antenna is intended for connecting a non-directional beacon (NDB) for broadcasting a radio signal in the frequency range from 190 to 1750 kHz. The antenna works as a grounded counterweight system and is mounted on a 12m or 24m long steel tower, a warning light (230V / 50Hz) is installed on top of the tower antenna in accordance with ICAO rules.

We will provide more information at: info@vyvoj.sk

Technical parameters

Operating supply voltage 230V ± 10% / 50 ± 2Hz
Backup power supply min. 3 hours of operation
Frequency range 190 - 1100 kHz
1100 - 1750 kHz
Broadcast mode N0N, A2A, A3E
Max. output peak power 500W
Artificial load Ra = 10 Ohm, Ca = 940 pF
Load impedance Ra = 1¸28 Ohm, Ca = 250¸ 1200 pF
Carrier frequency stability ±0.005%
Suppression of harmonic frequencies ≥ 40dBc
Modulation frequencies 400 ± 25 Hz, 1020 ± 50 Hz
Modulation depth 95 ±5%
Parasitic modulation ≤5%
Modulation envelope distortion ≤ 10%
Identification mark combination of Morse code characters (max. 4)
Telegraph speed adjustable - operating setting 7 words per minute, i.e. 5.6 Bd
Repetition of the identification mark 1 - 6 times per minute

Backing up transmitters


Time to switch to backup when performance drops below 55% max. 3 s
Time to switch to backup when the modulation depth drops below 75% max. 3 s
Time to switch to backup in the event of a brand failure max. 3 s
Climatic and mechanical conditions
NDB

Working temperature range 10°C to +30°C
relative air humidity up to 70%, at a temperature of +30°C
atmospheric pressure from 84 to 107 kPa
Vario

Working temperature range -20°C to +50°C
relative air humidity up to 98%, at a temperature of +35°C